Description
Technical Parameters
We are professional as one of the leading ion meter bante931 manufacturers and suppliers in China. Welcome to wholesale the high quality and durable laboratory equipment from our factory. And good after-sale service and timely delivery are offered.
Ion Concentration
- 2 to 5 points calibration, including the 8 concentration poin ts can be selected
- Direct ion concentration readout simplifies the measurement p rocess
- Automatic electrode diagnosis shows the calibration points an d slopes
- Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency
General Features
- Automatic temperature compensation ensures accurate readings over the entire range
- Auto-Read function senses and locks the measurement endpoint
- Calibration due alarm prompts user to calibrate the meter reg ularly
- Setup menu allows setting the number of calibration points, resolution, stability criteria, temperature unit, date and time, etc.
- Reset function automatically resumes all settings back to the factory defaults
- Expanded memory stores or recalls up to 500 data sets
- USB communication interface for data transfer and timed inter val readings
Optional Ion Selective Electrodes
Ammonium (NH4+ ), bromide (br- ), cadmium (Cd2+ ), calcium (Ca2+ ), chloride (Cl- ), cupric (Cu2+ ),
cyanide (Cn- ), fluoride (F- ), lodide (I- ), lead (Pb2+ ), nitrate (NO3- ), potassium (K+ ), silver (Ag+ ),
sodium (Na+ ), sulphide (S 2-) and ammonia (NH3+ )
| Ion | Range |
0.001~19999 (deponding on the range of ISE)
|
|
Resolution
|
0.001, 0.01, 0.1, 1
|
|
|
Accuracy
|
±0.5% F.S. (monovalent), ±1% F.S. (divalent)
|
|
|
Measurement Units
|
ppm, mg/L, mol/L, mmol/L
|
|
|
Calibration Points
|
2 to 5 points
|
|
|
Calibration Solutions
|
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000
|
|
| ORP | ORP mV Range |
± 1999.9mV
|
|
Resolution
|
0.1, 1mV, selectable
|
|
|
Accuracy
|
±0.2mV
|
|
| Temperature |
Range
|
0~105°C/32~221°F
|
|
Resolution
|
0.1°C/0.1°F
|
|
|
Accuracy
|
±0.5°C/±0.9°F
|
|
|
Offset Calibration
|
1 point, reading ±10°C
|
|
| Other specification |
Temperature Compensation
|
0~100°C, manual or automatic
|
|
Stability Criteria
|
Low or high
|
|
|
Calibration Due Alarm
|
1 to 31 days or off
|
|
|
Slope/Offset Display
|
Yes
|
|
|
Hold Function
|
Manual or auto-endpoint
|
|
|
Memory
|
500 data sets
|
|
|
Communication Interface
|
USB
|
|
|
Connector
|
BNC, 3.5mm jack socket
|
|
|
Display
|
Custom LCD (125 × 100 mm)
|
|
|
Power Requirements
|
DC5V, using AC power adapter, 220V/50Hz
|
|
|
Dimensions
|
210 (L) × 188 (W) × 60 (H) mm
|
|
|
Weight
|
1.5kg
|
Hot Tags: ion meter bante931, China, factory, suppliers, manufactures, wholesale